Third Schedule — Regulations, 2004
Third Schedule · Regulations, 2004
(Equivalent to Annex I of Commission Directive 2001/22/EC)
Methods Of Sampling For Offical Control Of The Levels Of Lead, Cadmium,
Mercury And 3-MPCD In Certain Foodstuffs
1. PURPOSE AND SCOPE
Samples intended for the official control of the levels of lead, cadmium, mercury
and 3-MCPD contents in foodstuffs shall be taken according to the methods
described below. Aggregate samples thus obtained shall be considered as
representative of the lots or sublots from which they are taken. Compliance with
maximum levels laid down in the Contaminants in Food Regulations shall be
established on the basis of the levels determined in the laboratory samples.
2. DEFINITIONS
Lot: an identifiable quantity of food delivered at one time and determined by the
official to have common characteristics, such as origin, variety, type of packing,
packer, consignor or markings. In the case of fish, also the size of fish shall be
comparable.
Sublot: designated part of a large lot in order to apply the sampling method on
that designated part. Each sublot must be physically separated and identifiable.
Incremental sample: a quantity of material taken from a single place in the lot or
sublot.
Aggregate sample: the combined total of all the incremental samples taken from
the lot or sublot.
Laboratory sample: sample intended for the laboratory
3. GENERAL PROVISIONS
Personnel
Sampling shall be performed by an authorised analyst as specified by the Act.
Material to be sampled
Each lot which is to be examined must be sampled separately.
Precautions to be taken
In the course of sampling and preparation of laboratory samples precautions must
be taken to avoid any changes which would affect the lead, cadmium, mercury
and 3-MCPD contents, adversely affect the analytical determination or make the
aggregate samples unrepresentative.
B
Incremental samples
As far as possible incremental samples shall be taken at various places distributed
throughout the lot or sublot. Departure from this procedure must be recorded in
the record provided for under 3.8.
Preparation of the aggregate sample
The aggregate sample is made up by uniting all incremental samples. It shall be at
least 1 kg unless not practical, e.g. when a single package has been sampled.
Subdivision of aggregate sample in laboratory samples for enforcement,
defence and referee purposes
The laboratory samples for enforcement, trade (defence) and referee purposes
shall be taken from the homogenised aggregate sample. The size of the laboratory
samples for enforcement shall be sufficient to allow at least for duplicate
analyses.
Packaging and transmission of aggregate and laboratory samples
Each aggregate and laboratory sample shall be placed in a clean, inert container
offering adequate protection from contamination, from loss of analytes by
adsorption to the internal wall of the container and against damage in transit. All
necessary precautions shall be taken to avoid change of composition of the
aggregate and laboratory samples which might arise during transportation or
storage.
Sealing and labelling of aggregate and laboratory samples
Each sample taken for official use shall be sealed at the place of sampling and
identified. A record must be kept of each sampling, permitting each lot to be
identified unambiguously and giving the date and place of sampling together with
any additional information likely to be of assistance to the analyst.
4. SAMPLING PLANS
Sampling should ideally take place at the point where the commodity enters the
food chain and a discrete lot becomes identifiable. The sampling method applied
shall ensure that the aggregate sample is representative for the lot that is to be
controlled.
Number of incremental samples
In the case of liquid products for which a homogeneous distribution of the
contaminant in question can be assumed within a given lot, it is sufficient to take
one incremental sample per lot which forms the aggregate sample. Reference to
the lot number shall be given. Liquid products containing hydrolysed vegetable
protein (HVP) or liquid soya sauce shall be shaken well, or homogenised by other
suitable means, before the incremental sample is taken. For other products, the
minimum number of incremental samples to be taken from the lot shall be as
given in Table 1. The incremental samples shall be of similar weight. Departure
from this procedure must be recorded in the record provided for under 3.8.
Table 1: Minimum number of incremental samples to be taken from the lot
Weight of lot
Minimum number of incremental samples to be
(kg)
taken
< 50
50 to 500
> 500
If the lot consists of individual packages, then the number of packages which shall
be taken to form the aggregate sample is given in Table 2.
Table 2: Number of packages (incremental samples) which shall be taken to form the
aggregate sample if the lot consists of individual packages
Number of packages or units in the lot
Number of packages or units to be taken
1 to 25
1 package or unit
26 to 100
About 5 %, at least 2 packages or units
> 100
About 5 % at maximum 10 packages or units
5. COMPLIANCE OF THE LOT OR SUBLOT WITH THE SPECIFICATION
The control laboratory shall analyse the laboratory sample for enforcement at
least in two independent analyses, and calculate the mean of the results. The lot is
accepted if the mean conforms to the respective maximum level as laid down in
the Contaminants in Food Regulations. It is rejected if the mean exceeds the
respective maximum level.