Second Schedule — Regulations, 2004
Second Schedule · Regulations, 2004
(Equivalent to Annex II of Commission Directive 98/53/EC)
Sample preparation and criteria for methods of analysis used in official checking of
the levels of aflatoxins in certain foodstuffs
1. Introduction
Precautions
Daylight should be excluded as much as possible during the procedure, since
aflatoxin gradually breaks down under the influence of ultra-violet light. As the
distribution of aflatoxin is extremely non-homogeneous, samples should be
prepared – and especially homogenised – with extreme care. All the material
received by the laboratory is to be used for the preparation of test material.
Calculation of proportion of shell/kernel of whole nuts
The limits fixed for aflatoxins in the Contaminants in Food Regulations apply to
the edible part. The level of aflatoxins in the edible part can be determined by
shelling samples of nuts `in shell' and the level of aflatoxins is directly
determined in the edible part,
homogenise the nuts `in shell' by taking them through the sample
preparation procedure. The sampling and analytical procedure must
estimate the weight of nut kernel in the aggregate sample. The weight of
nut kernel in the aggregate sample is estimated after establishing a suitable
factor for the proportion of nut shell to nut kernel in whole nuts. This
proportion is used to ascertain the amount of kernel in the bulk sample
taken through the sample preparation and analysis procedure.
Approximately 100 whole nuts are taken at random separately from the lot
or are to be put aside from each aggregate sample. The ratio may, for each
laboratory sample, be obtained by weighing the whole nuts, shelling and
re-weighing the shell and kernel portions. However, the proportion of shell
to kernel may be established by the laboratory from a number of samples
and so can be assumed for future analytical work. But if a particular
laboratory sample is found to be in contravention of any limit, the
proportion should be determined for that sample using the approximately
100 nuts that have been set aside.
2. Treatment of the sample as received in the laboratory
Finely grind and mix thoroughly each laboratory sample using a process that has
been demonstrated to achieve complete homogenisation.
B
In case the maximum level applies to the dry matter, the dry matter content shall
be determined on a part of the homogenised sample, using a procedure that has
been demonstrated to determine accurately the dry matter content.
3. Subdivision of samples for enforcement and defence purposes
The replicate samples for enforcement, trade (defence) and referee purposes shall
be taken from the homogenized material.
4. Method of analysis to be used by the laboratory and laboratory control
requirements
Definitions
A number of the most commonly used definitions that the laboratory will be
required to use are given below
The most commonly quoted precision parameters are repeatability and
reproducibility.
r = repeatability, the value below which the absolute difference between two
single test results obtained under repeatability conditions (i. e. same sample, same
operator, same apparatus, same laboratory, and short interval of time) may be
expected to lie within a specific probability (typically 95 %) and hence r = 2.8 . s r
s r = Standard deviation, calculated from results generated under repeatability
conditions
RSD r = relative standard deviation, calculated from results generated under
repeatability conditions [(S r /x) . 100], where x is the average of results over all
laboratories and samples
R = reproducibility, the value below which the absolute difference between single
test results obtained under reproducibility conditions (i.e. on identical material
obtained by operators in different laboratories, using the standardised test method)
may be expected to lie within a certain probability (typically 95 %); R = 2.8 s R
s R = standard deviation, calculated from results under reproducibility conditions
RSD R = relative standard deviation calculated from results generated under
reproducibility conditions [(S R /x).100]
General requirements
Methods of analysis used for food control purposes must comply whenever
possible with the provisions of points 1 and 2 of the Annex to Council Directive
85/591/EEC.
Specific requirements
Where no specific methods for the determination of aflatoxin levels in foodstuffs
are prescribed at Community level, laboratories may select any method provided
the selected method meets the following criteria
Criterion
Concentration range
Recommended value
Maximum permitted
value
All
Negligible
0.01 – 0.05 µg/kg
Recovery – Aflatoxin
60 to120 %
70 to 110 %
> 0.05 µg/kg
< 1.0 µg/kg
Recovery – Aflatoxins
50 to 120 %
70 to110 %
1-10 µg/kg
80 to 110 %
> 10 µg/kg
Precision RSD R
All
As derived from
2 x value derived from
Horwitz equation
Horwitz equation
Precision RSD R may be calculated as 0.66 times precision RSD R at the
concentration of interest.
Notes
Values to apply to both B 1 and sum of B 1 +B 2 +G 1 +G 2 ,
if sum of individual aflatoxins B 1 +B 2 +G 1 +G 2 are to be reported, then response of
each to the analytical system must be either known or equivalent,
the detection limits of the methods used are not stated as the precision values are
given at the concentrations of interest,
the precision values are calculated from the Horwitz equation, i. e.
RSD R = 2 (1-0,5 logC)
where
–
RSD R is the relative standard deviation calculated from results generated
under reproducibility conditions [(S R /x) .100]
–
C is the concentration ratio (i. e. 1 = 100 g/100 g, 0,001 = 1 000 mg/kg).
This is a generalised precision equation which has been found to be independent
of analyte and matrix but solely dependent on concentration for most routine
methods of analysis.
Recovery calculation
The analytical result is to be reported corrected or uncorrected for recovery. The
manner of reporting and the level of recovery must be reported. The analytical
B
result corrected for recovery is used for checking compliance (see First Schedule,
points 5.2.2, 5.3.2, 5.4.2, 5.5.1.2 and 5.5.2.3.
The analytical result has to be reported as x ± U whereby x is the analytical result
and U is the expanded measurement uncertainty, using a coverage factor of 2
which gives a level confidence of approximately 95 %.
Laboratory quality standards
Laboratories must comply with Council Directive 93/99/EEC.