Art. 16 Building Act (LC) - Boundary Distance and Building Distance
Art. 16 BauG - Boundary Distance and Building Distance · Boundary Distance and Building Distance
1. The boundary setback is the distance between the projected facade line and the parcel boundary. The building setback is the distance between the projected facade lines of two buildings.
2. Protruding building elements are not considered in the setback calculation. Exceptions are subject to specific regulations regarding projections in road legislation and fire safety regulations.
3. Underground structures are not subject to the setback rules and can be built up to the property boundaries. For certain structures, municipalities can provide exceptions in their BZR.
4. Setbacks in relation to roads are determined by road legislation and municipal regulations.
5. If municipalities establish a minimum setback based on facade height, the definition of facade height is as per IVHB. Municipalities can issue provisions on the inclusion of dormers and other similar structures for calculating facade height.