Art. 2 DECREE concerning the frequency and tariffs for compulsory chimney sweeping (AFTRO) - [ 7 ]
Art. 2 AFTRO - [ 7 ] · [ 7 ]
1. Fixed smoke flues within the meaning of Article 17b of Act [A] must be cleaned regularly, taking into account the type of fuel used, the degree of utilization, and current technology.
2. Where this Ordinance prescribes two cleanings per year, at least one of them must take place during the period when the installations are in use.
3. As a general rule, mandatory chimney sweeping shall take place according to the following frequencies
1. Installations for heating premises, hot water preparation, and cooking (excluding gas cookers)
1.1 Solid fuel installations
1.1.1 natural draught: 2 times per year
1.1.2 with flue gas regulation: 2 times per year
1.1.3 Supplementary installation, living room fireplace, stove-fireplace, etc.: 1 time per year
1.2 Liquid fuel installations with burner
1.2.1 oil evaporation (oil furnace): 1 time per year
1.2.2 forced air with a power output of 70 KW or less: 1 time per year
1.2.3 forced air with a power output greater than 70 KW: 2 times per year
1.3 Gaseous fuel installations with burner
1.3.1 forced air with a power output of 70 KW or less: 1 time every 2 years
1.3.2 forced air with a power output greater than 70 KW: 1 time per year
1.3.3 atmospheric: 1 time every 2 years
1.3.4 with sealed combustion chamber: 1 check every 2 years
1.4 Installations used occasionally or temporarily
- In the event of occasional or temporary use of an installation and at the request of its owner or user, the master chimney sweep may reduce the number of cleanings if circumstances justify it.
1.5 Multi-fuel heating installations
- If an installation operates alternately with solid, liquid, or gaseous fuel, the cleaning frequencies specified under paragraphs 1.1, 1.2, and 1.3 of this Ordinance shall apply by analogy, taking into account the duration of use of the installation with each of the aforementioned fuels.
2. Professional and industrial heating installations
2.1 Professional and industrial heating installations must be swept as often as their characteristics, operating instructions, and use require.
- The frequencies set for the installations mentioned in Article 2, paragraph 1, of this Ordinance must in principle be considered minimum requirements.
- Professional and industrial heating installations are understood to be those that do not fall within the categories mentioned in Article 2, paragraph 1, of this Ordinance.
2.2 Installations for the incineration of municipal waste and special waste are not subject to this Ordinance.