Legislator Case Law & Legislation
801.100 KRGLPTC CH-GR

Art. 76 Spatial Planning Act for the Canton of Graubünden (KRG) - 2. Additional Structures and Installations

Cantonal Building Regulations - Setbacks
Open official source Full Act (137 Articles) Machine-readable Markdown (.md)

Art. 76 KRG - 2. Additional Structures and Installations · 2. Additional Structures and Installations

1. For open covered areas such as shelters and similar structures, the boundary distances for buildings apply, measured from the eaves to the property boundary.

2. Freestanding walls, retaining walls (buttress walls), embankments, and the like may be constructed at the boundary, provided they are not higher than 1.0 m. If they exceed the height of 1.0 m, they must maintain a boundary distance equivalent to the excess height, but no more than 2.5 m.

3. For excavations, a boundary distance of 0.5 m, measured from the top edge of the trench slope, must be observed. If the neighboring property is secured by a retaining wall or comparable structural measures, no boundary distance needs to be maintained.

4. Enclosures such as fences, walls, and wooden partitions up to a height of 1.5 m from the relevant terrain may be placed at the boundary. Taller enclosures must be set back by an amount equivalent to the excess height, but no more than 2.5 m.

5. Hedges may be planted at a distance of 0.5 m from the boundary, provided they are trimmed back annually to the boundary and to a height of 1.5 m from the relevant terrain. Taller hedges must be set back by an amount equivalent to the excess height, but no more than 2.5 m.

← Art. 75 KRG - Building Distances Spatial Planning Act for the Canton of Graubünden (KRG) - Subject Matter Art. 77 KRG - 3. Reductions, Reservations →

Need to analyze how this provision applies to your matter?

Cross-reference this statute against case law, commentaries, and related legislative provisions inside Legislator AI.

Open in Legislator →

Court Decisions Applying This Provision (36)

VR3 2024 89 · gr (Art. 76 Abs. 1 KRG)
Appeal Against Dismissal of Objection to Building Permit for Garden Shed
Cited to establish the general rule regarding setback distances for covered areas like shelters.
PVG 2024 9 · gr (Art. 76 Abs. 2 KRG)
Solar Tracker Boundary Distance Dispute
Cited in the operative part as the basis for applying a minimum cantonal setback distance of 2.5 m to the solar tracker.
R 2024 71 · gr (Art. 76 Abs. 1 KRG)
Appeal Against Building Permit for Carport Violating Setback Distances
The court determined that the carport structure falls under this provision, which dictates the applicable setback distance.
R 2023 35 · gr (Art. 76 Abs. 1 KRG)
Pergola Setback and Building Permit Classification Appeal
The court determined that the pergola does not fall under the category of 'open covered areas' and thus does not have to adhere to setback requirements.
R 2022 32 · gr (Art. 76 Abs. 4 KRG)
Municipal Building Inspection Appeal Regarding Concrete Blocks and Safety Measures
Applied in the reasoning to determine that the concrete blocks placed on the forecourt did not constitute a materially unlawful situation as they qualified as a partial enclosure.
R 2020 3 · gr (Art. 76 Abs. 1 i.V.m. Art. 75 Abs. 1 KRG)
Municipality v. Property Owner: Unauthorized Patio Roof Setback Violation
This provision, concerning minimum separation distances for open covered areas and buildings, was the direct legal basis for rejecting the building permit, as the structure violated the required distance.
R 2019 71 · gr (Art. 76 Abs. 4 KRG)
Applicant v. Municipality Regarding Wire Mesh Fence Permit Denial
Although cited in the reasoning, the key decision point for allowing the appeal was not based on this article's provisions regarding fence height, but rather on the subsequent development rendering the initial objection moot.
R 2016 72 · gr (Art. 76 Abs. 3 KRG)
Appeal Regarding Building Permit Approval Contesting Access Road Validity in Quarter Plan
Cited in the reasoning concerning the distance rules for excavations/retaining walls.
R 2016 72 · gr (Art. 76 KRG)
Appeal Regarding Building Permit Approval Contesting Access Road Validity in Quarter Plan
Cited in the reasoning regarding distance requirements for 'other buildings and structures'.
R 2014 97 · gr (Art. 76 Abs. 1 KRG)
Appeal Regarding Building Permit for Garage Alterations and Setback Non-Compliance
Cited in the reasoning to define setback requirements for walls higher than 1m.
R 2014 97 · gr (Art. 76 Abs. 2 KRG)
Appeal Regarding Building Permit for Garage Alterations and Setback Non-Compliance
Cited in the reasoning to discuss the setback requirements for retaining walls.
A 2015 14 · gr (Art. 76 Abs. 4 Satz 1 KRG)
Fence Permit Denial Based on Private Easement Obstruction
Applied to grant the building permit for the eastern part of the fence based on height regulations.
A 2015 14 · gr (Art. 76 Abs. 4 Satz 1 KRG)
Municipality v. Applicant Regarding Fence Permit Denial Over Easements
Basis for partially granting the appeal (R 15 24) regarding the building permit for the eastern part of the fence.
R 2014 112 · gr (Art. 76 Abs. 2 KRG)
Property Boundary Wall Classification and Construction Violation
The court applied the standard for setback distances for retaining walls exceeding 1.0 m in height, as this was the core issue regarding the boundary encroachment of the wall.
R 2014 112 · gr (Art. 76 Abs. 2 KRG)
Property Boundary Wall Classification and Construction Violation
The court cited this provision (implicitly/explicitly through the application of the distance rule) when determining that the wall had to maintain a 1.8m distance, which stems from Art. 76 Abs. 2 KRG's setback rules for backfilled walls.