Legislator Case Law & Legislation
710.11 RPBRRELATEC CH-FR

Art. 80 Regulation Implementing the Act on Spatial Planning and Construction (ReLATeC) - Indices - Floor Area Ratio (Index 8.2 Annex IVHB)

**Buildings - Building Regulations (Art. 119 ff. RPBG) - Building Components, Stories, Utilization Figures, and Distances (Art. 119 Para. 2, 130, 132 ff. RPBG)**
Open official source Full Act (139 Articles) Machine-readable Markdown (.md)

Art. 80 RPBR · Floor Area Ratio (Index 8.2 Annex IVHB)

1. In residential zones with open construction, the floor area ratio according to municipal regulations must not be less than 0.6.

2. In industrial zones, where no volume ratio is applicable (Item 8.3 Appendix IVHB), the floor area ratio must not be less than 0.75.

3. In zones with open construction, the municipal regulations may forgo specifying the floor area ratio, provided that the other regulations suffice.

4. For the conversion of an existing building within the construction zone, the established values for the relevant zone need not be adhered to, if

a) the building is listed in the zoning plan;

b) the conversion occurs within the original volume;

c) due to the plot area, the floor area ratio for the corresponding zone cannot be maintained during a conversion within the original building volume;

d) during the conversion, the special character of a townscape, locality, neighborhood, or street, as well as the appearance of the building to be converted, is taken into account;

e) in case of parcel division, the floor area ratio value of the zone is applied to the building and any potential new constructions;

f) the other building regulations are complied with.

5. Areas with a floor height of less than 1.50 m are not considered in the calculation of the floor area ratio.

6. Renovated buildings that meet at least Class B of the Cantonal Building Energy Certificate (GEAK), and new buildings that comply with Class A of the GEAK, are granted a bonus of 10% on the floor area ratio specified in the municipal regulations.

7. In zones with closed construction, the floor area ratio is not applicable.

← Art. 79a RPBR - Numerals - Relevant Land Area Regulation Implementing the Act on Spatial Planning and Construction (ReLATeC) - General Provisions Art. 81 RPBR - Numbers - Overbuilding Index (Sec. 8.4 Annex IVHB) →

Need to analyze how this provision applies to your matter?

Cross-reference this statute against case law, commentaries, and related legislative provisions inside Legislator AI.

Open in Legislator →