Art. 64 Building Regulation (BauV) - Regulations for Living and Working Spaces 1 Lighting, Sun Exposure, and Ventilation
Art. 64 Building Regulation (BauV) · Regulations for Living and Working Spaces 1 Lighting, Sun Exposure, and Ventilation
1. Living and working spaces must receive sufficient light and air directly from outside. The window area should be at least one-tenth of the floor area and must be capable of being opened to a sufficiently large extent at all times.
2. In family dwellings, the main daytime living areas (living room and children's playroom) must not be oriented towards the north.
3. Exclusive artificial lighting and ventilation are permitted for rooms in industrial buildings, commercial buildings, hospitals, and similar, which cannot be naturally lit and ventilated or can only be so with disproportionate effort.
4. Dining areas of catering establishments and smoking rooms in such establishments must be equipped with an adequate mechanical ventilation system for both supply and exhaust.
5. For rooms without a mechanical supply and exhaust air system, an air purifier with a HEPA particulate filter is sufficient.