Art. 4 Building Ordinance (BauV) - Floors

Chapter 1: Substantive Building Regulations - Section 1: Definitions of Terms
Open official source Full Act (70 Articles) Machine-readable Markdown (.md)

Art. 4 Building Regulation · Floors

1. Each story that is neither considered as a basement nor as an attic is counted as a full story.

2. A basement is defined as a floor with its finished ceiling surface no more than 1.30 meters above the benchmark level.

3. An attic is defined as a floor within the roof space, having a knee wall of no more than 0.90 meters, and with roof surfaces that are interrupted by dormer structures to no more than half of the facade's length.

4. The knee wall is measured from the top of the finished floor to the underside of the finished roof structure. An attic story also includes a penthouse that is set back from the facade-to-roof intersection, including roof overhang and eaves, at an angle of 45° above the topmost full story. On the two opposing short sides of the building, the penthouse may be built flush with the facade.

5. Paragraph 4 applies analogously to shed roofs.

6. The building regulations of the municipality determine to what extent stories are considered as visible on the valley side.

← Art. 3 BauC - Method of Construction Building Ordinance (BauV) - Utilization Ratio Art. 5 Construction Ordinance →

Need to analyze how this provision applies to your matter?

Cross-reference this statute against case law, commentaries, and related legislative provisions inside Legislator AI.

Open in Legislator →

Court Decisions Applying This Provision (4)

OG ARGVP 2011 3566 · ar (Art. 4 Abs. 1 BauV)
Zoning Compliance: Chargeable Land Area, Uppermost Floor Classification, and Projection Width
Cited to establish that any storey not qualifying as a basement or attic storey is counted as a full storey, leading to the project exceeding the maximum number of full storeys.
OG ARGVP 2011 3566 · ar (Art. 4 Abs. 3 BauV)
Zoning Compliance: Chargeable Land Area, Uppermost Floor Classification, and Projection Width
Cited in the context of determining whether the top storey qualifies as an attic storey based on the attic space criteria.
OG ARGVP 2011 3566 · ar (Art. 4 Abs. 4 BauV)
Zoning Compliance: Chargeable Land Area, Uppermost Floor Classification, and Projection Width
Cited in the context of defining attic storeys, specifically regarding the knee wall height and the setback angle for attic storeys.
Verwaltung ARGVP 2001 1375 · ar (Art. 4 lit. a BauV)
Balcony Removal Upheld; Driveway Resurfacing Deemed Maintenance
The revised pathway sanitation was considered maintenance/renewal according to this provision, meaning it was not subject to a building permit requirement.